Articulation Gear Case Study

Download the Articulation Gear Case Study (PDF)

    

Application:

Medical Instrument – Interior Mechanical Component

Functional
Requirements:

Mechanical Strength, Precision for overmolding

Competing
Technologies:

Plastic Injection Molding, Machining

Overall Size:

LxWxH = 0.460in x 0.386in x 0.895 in

Part Weight:

6.1 grams

Material:

MIM-17-4 PH

 

 Why MIM? 

  • Cost savings - 20% the cost of machined part
  • High production rates. Over 10k per cav/wk
  • Strength over plastic
  • Good surface finish on gear teeth
  • Little material waste
  • Fewer burr removal problems

MIM Issues  

  • Roundness < 0.003 in required for shut-off surface during over-mold process 
         
    Mold flow uniform in area of shut-off diameter 
           
    Gravity effects negligible and setter drag isolated away from critical diameter 
           C
    oining step prepared for but not necessary due to process capability

  • Stability during processing / Quality of gear teeth
         
    Custom setters
            Interrupted gear teeth shut-offs

Economics

  • No individual part handling once stacked from molding
  • No secondary operations

  • Qualified with same material part through processing to allow for smaller lot size until volume increases

Conclusion

  • Good application for MIM
  • Fast turnaround from release of model to part approval

  • Cost saving for customer and profitable for MIM supplier

Download the Articulation Gear Case Study (PDF)